Détecteur portable multigaz GX-6100
6-gas simultaneous | IP-67 | 28 hr Li-ion runtime | Internal pump 0.45 LPM | 2 interchangeable smart sensor slots
ERE Inc. propose des produits pour que vous puissiez surveiller vos contaminants. Qu'il s'agisse de bactéries, de gaz COV ou encore de particules de poussière, ERE Inc. a l'équipement qu'il vous faut. Appelez notre service à la clientèle, ils se feront un plaisir de vous aider.

6-gas simultaneous | IP-67 | 28 hr Li-ion runtime | Internal pump 0.45 LPM | 2 interchangeable smart sensor slots

10–30 VDC | 4-20 mA + Modbus RTU output | NEMA 4X explosion-proof cast aluminum | -40°C to 50°C operating temp | UL/CSA Class I Div. 1 Groups B, C, D

IP-67 | 2 AAA batteries, up to 9,000 hrs | T90 ≤30 sec | -20°C to +50°C | ATEX/IECEx + C/US Class I Div 1

• Detection Range: 0.01 - 50.0 ppm (TAC) | • Stack Colour: White + Gold Spot | • Lamp: 10.0 eV | • Calibration Points: 2 points

• Detection Range: 0.001 - 10 ppm | • Stack Colour: White | • Lamp: 10.6 eV | • Calibration Points: 2 points

Accessoire de détection de gaz

Includes: Transport Case (Part # IS-875405)

• Measuring Frequency: One Minute | • Temperature Stability: Internally heated | • Flow Rate: Sample flow rate ≥ 100 ml/min

• 20 cm Flexible Probe | • Box Spanner

Operating Temp: -5°C to 45°C | Bump Test Time: 8–15 sec | Gas Flow: 300 mL/min | Gas Connections: 3 | Compatible: Pac 3500/5500/6000/6500/7000/8000/8500

IP68 | 64×84×20 mm | 106 g (113 g with clip) | −30 °C to +55 °C | cCSAus / IECEx / ATEX / CE

IP68 | 64×84×20 mm / 106 g | 2-year battery (O2: 1 yr) | −40°C to +55°C | ATEX / IECEx / cCSAus

Measuring Range: 0-2000 ppm | Resolution: 1 ppm | Alarm 1: 25 ppm | Alarm 2: 50 ppm

48×130×61 mm | 220–250 g | IP 54 | -20 to +50°C | ~150 h NiMH / ~180 h HC battery | ATEX/IECEx/CSA certified

5 gases simultaneous | LEL/O2/H2S/CO + 1 toxic/IR channel | IP66/68 | ATEX, CSA, IECEx, MED | 4.58 oz / 2.9"W x 2.6"H x 1.06"D

4 Gases (LEL/O2/H2S/CO) | IP66/68 | 3.52 oz / 100 g | 25 hr battery | -20°C to +50°C | ATEX, CSA, IECEx, MED

1.6 oz / 45 g | IP66/68 | ATEX, IECEx, CSA | CR2450 battery, up to 4,000 hrs | Diffusion sampling, −20°C to +50°C

Exposure level: 4.0 ppm • hr | Minimum detectable limit (8 hours): 0.50 ppm | 50/Box

Exposure Range For Badge: 4 - 300 ppm•hr | Min. Detectable Limit (8 hrs): 0.5 ppm | 10/Box

IP 67 | 490 × 300 × 300 mm / 10 kg | 120 h battery (24 Ah) | ATEX / IECEx / CSA-US Zone 0 | Up to 25 units wireless fenceline

AsH3 0–15 ppb | H2Se 0–200 ppb | 4-20 mA output | 41–95°F (5–35°C) operating | Panel: 24VDC / Desktop: 100-220VAC

HCHO 0–0.4 ppm (30 min) / 0–1.0 ppm (15 min) | Photoelectric photometry + colorimetric tablet | ±20% accuracy | 4 AA batteries (~12 hr) | 85×190×40 mm, 500 g