Overview

The RKI AirLink VOC Pro is an explosion proof fixed photoionization (PID) detector for volatile organic compounds, with a wireless radio plus 4-20 mA and RS-485 Modbus outputs as standard. It runs on 12 to 35 VDC and takes a 10.0, 10.6 or 11.7 eV lamp.

  • PID sensor for VOCs: 10.0 eV, 11.7 eV, 10.6 eV low ppm or 10.6 eV ppm lamp
  • Ranges from 0-10.00 ppm up to 0-2,000 ppm, depending on the lamp
  • Wireless 900 MHz or 2.4 GHz radio plus 4-20 mA (3-wire) and RS-485 Modbus outputs
  • Wire powered (3-wire) 12 to 35 VDC, 2 W maximum
  • 2 configurable alarms with amber and red LEDs; 2 optional dry-contact relays
  • Magnetic switches for non-intrusive calibration, settings and diagnostics
  • CQPSUS explosion / flame proof Class I Div 1 and 2 Groups B C D
  • RKI publishes PID response factors to convert isobutylene readings to your VOC

Part numbers are RKI's (lamp base + range suffix + W). The 10.6 eV ppm sensor is also offered at 0-100 ppm, alarm relays and the remote sensor kit are options: ask for them in your quote. Request a quote for pricing and availability.

Specifications

Sensor Type
Photoionization detector (PID), calibrated with isobutylene
PID Lamps and Ranges
10.0 eV 0-10.00 / 20.00 / 50.00 / 100 ppm; 11.7 eV 0-100 ppm; 10.6 eV low ppm 0-10.00 / 20.00 / 50.00 ppm; 10.6 eV ppm 0-200 / 500 / 1,000 / 2,000 ppm
Part Number Base
10.0 eV 66-6195-XX-W / 11.7 eV 66-6194-XX-W / 10.6 eV low ppm 66-6192-XX-W / 10.6 eV ppm 66-6193-XX-W (XX = range)
Operating Voltage
Wired power (3-wire) 12 to 35 VDC
Power Draw
2 W maximum
Protection
EMI filter / 4-20 mA and RS-485 surge suppression
Wireless Radio
900 MHz (200 mW) or 2.4 GHz (125 mW), 1 to 1.5 miles range
Networks
52 networks (900 MHz) or 78 networks (2.4 GHz), 255 addresses per network
Outputs
Wireless / 4-20 mA (3-wire) / RS-485 Modbus / fault terminal / optional 2 dry-contact relays with 4 A fuses
Display
102 x 64 graphic LCD, transflective (sunlight readable), white LED backlight
Interface
3 push-buttons (MENU / ADD / SUB) + 3 magnetic non-intrusive switches
Alarm Settings
2 configurable alarm LED and optional relay set points
Operating Temperature
-40 to +54 °C (-40 to +130 °F)
Remote Sensor Kit (Optional)
With enclosure (5 pin): PID sensor up to 35 ft
Hazardous Location Approvals
Main enclosure and sensor housing CQPSUS explosion / flame proof Class I Div 1 and 2 Groups B C D; NEMA 3, 4, 4X, 7 (B C D), 9 (E F G)
Compatible Controllers
Wireless: AirLink 7010, AirLink 7032 / analog: RKI Beacon 110, 200, 410A, 800 and most DCS / PLC systems
Dimensions
5.5 x 6 x 7 in (8 x 17 in max with attachments)
Weight
6 lb
Warranty
1 year electronics and PID sensor (2 months for the 11.7 eV lamp)

Documents

In-house service

Calibration and repair

Send it to our Montreal service team. We evaluate the instrument and send a detailed quote before any work starts.

Start a service request

Parts & accessories

  • Price on quote

Compare with similar models

RKI Instruments · Fixed Gas Detector
SpecThis modelRKI AirLink VOC Pro Wireless PID VOC DetectorPrice on quote RKI VOC Pro Explosion-Proof PID VOC Detector / TransmitterPrice on quote RKI H2S Rig Monitor for Temporary Drill SitesPrice on quote
SensorPIDPID—
Range0-10 to 0-2000 ppm—0-100 ppm H2S
Power12 to 35 VDC12 to 35 VDC12 VDC

Questions, answered

How fast will I get a price?

Send the quote request and a specialist replies within 4 business hours, Monday to Friday, 8:00 to 4:30 ET.

Can we pay on account or by purchase order?

Yes. With established credit, terms are Net 30 days, and you can send your purchase order with the quote request. We also accept Visa, Mastercard and American Express.

How is shipping charged?

On quotes and account orders, freight is F.O.B. Montréal: the carrier charge is worked out at shipment from the packed weight and dimensions, and added to your invoice. In-stock items can also be picked up the same day in Montréal (8605 rue du Champ-d'Eau).

Can I return it?

Yes, within 30 days of purchase, with a return authorization number from customer service first. A 25% restocking fee applies, unless it is a defect covered by the warranty. Special orders, hazardous materials, flammable liquids and gases can't be returned. Return policy

Can ERE calibrate or repair it?

Yes. Our Montréal service shop calibrates and repairs it in-house. Request service

What warranty does it carry?

The manufacturer's warranty applies. The exact terms are in the warranty document. Read the warranty

Since 1994Supplying labs and field crews
30,000+Customers across North America
AuthorizedBrand distributor
4 hrTypical quote turnaround