Buck Bio-Culture™ Biocontaminent Sampling Pump
• Flow rate: 30 - 120 LPM
Air sampling pumps for industrial hygiene, asbestos and IAQ work: Gilian GilAir, 800i, 5000, 10i and 12, Buck Libra, Elite and intrinsically safe Allin, Zefon Escort, high-volume area pumps and bioaerosol pumps, from 1 mL/min to 120 L/min. Rent or buy.

• Flow rate: 30 - 120 LPM

10–20 LPM ±5% constant flow | 826 g | 4″H × 6″W × 5.25″D | NiCad battery, 5 h @ 15 LPM | 1/2/5/10 min programmable timer

• Flow Rate: 15 LPM | • Accuracy: ±5% | • Housing: PC/ABS plastic | • Battery: Rechargeable nickel metal hydride (NiMH)

Flow Rate: 1 - 5,100 cc/min (total)

• Flow rate: 5 - 20 LPM

0–30 LPM flow range | 1/10 hp motor | 120V AC / 1.6A | 12 lbs | Internal filter/muffler

3–14 LPM flow range | 23-stroke diaphragm | 120V / 93.2W | 11 lbs | 14 × 10 × 6 in

Flow range: 0.1–0.6 / 0.8–5.0 / 3.0–12.0 LPM (model-dependent) | Low flow with holder: 5–2999 cc/min | Certifications: UL 913 & CAN/CSA-C22.2 Class I/II/III Div 1 Groups A-G T3 | Battery: Rechargeable NiMH | Backpressure compensation: up to 50" w.c. @ 2 LPM

Flow Rate: 5-5000 cc/min

0.8–5.0 LPM flow (LP-5) | 4.5"H × 4"W × 2"D | 19 oz (538 g) | NiMH 4.8V 2.15 Ah, 20+ hr runtime | CE EMC Directive 89/336/EEC

0.8–4.0 LPM flow range | 4.5″H × 4″W × 2″D, 16 oz (453 g) | NiMH 4.8V 2.15 Ah, ~2–2.5 hr recharge | Op temp 0–40°C | CE EMC Directive 89/336/EEC

• Flow range: 0.5 - 3 LPM (total)

• Flow range: 0.5 - 3 LPM (total)

Flow Rate: 2 - 30 LPM | Includes: sampling mast, support tip, hose & manual

100-240VAC, 50/60Hz, US Cord

GilAir-3: 1–3,000 cc/min | GilAir-5: 1–5,000 cc/min | ±5% constant flow accuracy | NiMH battery, 8 hr run time | UL Intrinsically Safe (Class I Div 1 A/B/C/D; ATEX/IECEx)

Range: 1 - 350 cc/min

• Flow Rate: 500 - 3,000 cc/min (total) | • Certifications: Not Intrinsic Safe

Flow Rate: 0.5–3 LPM | Accuracy: ±2.5% (1–3 LPM) | Weight: 23 oz (652 g) | IP66 rated | Battery: 4.8V NiMH 2.8 Ah

200–800 cc/min flow range | ±5% constant flow control | 80" H₂O max back pressure | >8h runtime / <4h charge (NiMH) | EN 1232 Type-G & Intrinsically Safe (ATEX)

20–5,000 cc/min flow range | ±5% constant flow control | NiMH battery, <4 hr charge, 8 hr min run | 580 g (20.5 oz), 3.2×5.4×2.3 in | Intrinsically Safe: US/CAN NRTL (FM) Class I Div 1 A-D; ATEX II 1G Ex ia IIC T4; EN 1232 Type P

4–12 LPM flow range | 19.5 oz (580 g) | 3.2" × 5.4" × 2.3" | NiMH battery, <4 hr charge | 0–45°C operating temp

4–10 LPM flow range | ±5% constant flow control | NiMH battery, <4hr charge | 8hr min runtime at 4 LPM | 23 oz (654 g), 3.2"×5.4"×2.3"
ERE carries personal, area and bioaerosol sampling pumps, sorted here by flow. Low-flow pumps for sorbent tubes include the Gilian LFS-113 (1 to 350 cc/min) and 800i (200 to 800 cc/min, built for back pressure on VOC methods). General personal pumps include the GilAir-3 and GilAir-5, the GilAir Plus, the Gilian 5000, the Buck Elite and Libra Plus and the Zefon Escort ELF; the Buck Allin is intrinsically safe. Higher flows come from the Gilian 10i and Gilian 12 (to 12 L/min), the AirCon-2 area sampler (2 to 30 L/min) and Zefon high-volume pumps, and the Buck Bio-Culture runs 30 to 120 L/min for bioaerosols.
ERE rents and sells air sampling pumps and services and calibrates them. Tell us the method and media, and we will match a pump.
The method sets it. Sorbent tubes for VOCs and gases run at low flows, from a few cc/min to about 1 L/min; filter cassettes for dust, metals and asbestos run at 1 to 5 L/min; spore traps run at 5 to 15 L/min; and area or clearance sampling uses high-volume pumps up to 30 L/min. Pick a pump whose range covers your method's flow with margin. See our air sampling pump guide.
Yes, where flammable gases or vapours may be present. The Buck Allin and Allin Plus are personal samplers certified for those locations; the Gilian BDX-II, for example, is not intrinsically safe and is built for asbestos and lead abatement work.
NIOSH methods call for flow within ±5% before and after each sample. Constant-flow pumps such as the Gilian 5000, 10i and 800i hold ±5%, and the Zefon Escort ELF adds an internal flow sensor. Check the flow with a calibrator before and after every sample, with the full sampling train in line.
Rent for a single project or a peak in workload, buy for a steady program. Rental pumps are calibrated and tested before they ship. Our rental guide compares the costs.