A laboratory hot plate is a flat heated surface for warming beakers, flasks and dishes; a hot plate stirrer adds a magnetic drive under the plate so a stir bar mixes the liquid while it heats. Choose a heat-only plate for evaporating or warming, a hot plate stirrer when the sample must be mixed as it heats, and a stir-only unit when it must not be heated. Then match plate size, plate material, control (analog or digital) and capacity to your vessels.
What is the difference between a hot plate and a hot plate stirrer?
A hot plate only heats; a hot plate stirrer heats and spins a magnetic stir bar in the vessel. About 320 searches a month in Canada are for "laboratory hot plate". The OHAUS Guardian line sold by ERE lists models for each function: heating (HP), heating and stirring (HS) and stirring only (ST). For the stirring side of the choice, see our magnetic stirrer guide.
| Series | Control | Functions and plates listed | Capacity listed |
|---|---|---|---|
| Guardian 2000 | Analog knob; temperature range listed as 50 to 500 °C | Heating, heating and stirring, or stirring only; 4 x 4 in. or 7 x 7 in. ceramic, 5.3 in. ceramic-coated stainless steel (resin on two stir-only models) | 15 L |
| Guardian 3000 | Digital LCD with hot top indicator | Heating and stirring; 4 x 4 in. or 7 x 7 in. ceramic, 5.3 in. ceramic-coated stainless steel | 15 L |
| Guardian 5000 | Digital; heating models reach up to 550 °C with 3 temperature control modes; 50 to 1,800 rpm | Heating, heating and stirring, or stirring only; 7 x 7 in. or 10 x 10 in. ceramic, 5.3 in. ceramic-coated aluminum | 20 to 22 L |
| Guardian 7000 | Digital LCD with temperature, speed and time settings; 60 to 1,600 rpm | Heating and stirring; ceramic or aluminum plates, 5.3 to 10 in. | 15 to 20 L |
Which plate material and size should you choose?
Pick the plate size to match the base of your largest vessel, and the material to the chemistry and cleaning routine. The Guardian range lists ceramic plates (4 x 4 in., 7 x 7 in. and 10 x 10 in.), ceramic-coated stainless steel and ceramic-coated aluminum round plates (5.3 in.), and resin on the stir-only 2000 models. A plate that is clearly larger than the flask base heats a wider area, while a small plate suits a single round-bottom flask and takes less bench space.
The Guardian 7000 also has a chemical-resistant SmartHousing designed to channel spills away from internal components, which matters when a bench handles solvents and acids. Confirm the housing and plate against your sample's safety data sheet under WHMIS rules for laboratories before heating anything flammable.
Is analog or digital control better?
Use analog control for everyday warming and stirring where a few degrees do not matter, and digital control when you must set, read and repeat a temperature. The Guardian 2000 uses simple knobs to set heating and stirring. The Guardian 3000 adds a bright LCD with temperature and speed readouts and a hot top indicator that lights when the plate is above 40 °C. The Guardian 5000 and 7000 add more control options, including 3 temperature control modes on the 5000 for quick heating or precise heating without overshoot.
For a sample that must hold a set temperature, add the optional temperature probe so the controller reads the liquid rather than the plate. The Guardian 3000 accepts the probe, and the Guardian 5000 "K1" kits ship with the temperature probe and probe holder included.
How do you choose the right hot plate for your lab?
- Define the function. Heating only (evaporation, warming), heating and stirring (dissolving, reactions), or stirring only (temperature-sensitive samples).
- Size the plate and capacity. Match the plate to your largest vessel base, and check that the listed capacity (15 L on the 2000 and 3000, 15 to 20 L on the 7000, up to 22 L on the 5000) covers your maximum volume.
- Set the control level. Analog for general use; digital when the method specifies a temperature or speed; a probe when the sample, not the plate, must hold temperature.
- Check the maximum temperature. The 2000 lists 50 to 500 °C and the 5000 heating models reach up to 550 °C. Compare with the boiling and flash points on the safety data sheet.
- Plan the accessories. Support rods and clamps, PTFE spin bars (2.5 cm to 10 cm) and sectional blocks for 12, 15, 17 and 21 mm vials are listed under OHAUS hotplates and stirrers accessories.
Browse the full range in the hotplates and stirrers collection. Large vessels and viscous media may call for an overhead stirrer instead; our orbital shaker guide covers the other common way to mix samples in flasks.
How do you use a hot plate safely?
Use a vessel that sits flat on the plate, never heat a closed container, and keep flammable solvents away from an open hot surface. Check the safety data sheet for boiling point and flash point before you set a temperature, and keep the plate below the temperature at which your sample decomposes. Read the WHMIS requirements for the products on your bench, and treat a plate as hot until the display or hot top indicator says otherwise.
Frequently asked questions
What is a hot plate used for in a lab?
It warms, evaporates or heats liquids and solids in beakers, flasks and dishes. A hot plate stirrer also mixes the liquid with a magnetic stir bar while it heats, which helps dissolve solids and keeps the temperature even.
What is the difference between a hot plate and a hot plate stirrer?
A hot plate only heats. A hot plate stirrer heats and stirs. ERE lists heating-only, heating-and-stirring and stirring-only models in the OHAUS Guardian range.
How hot does a laboratory hot plate get?
It depends on the model. The Guardian 2000 lists 50 to 500 °C and the Guardian 5000 heating models reach up to 550 °C. Always stay well below the flash point and decomposition temperature of your sample.
Does ERE stock laboratory hot plates?
The OHAUS Guardian models above are in our catalogue. Availability varies by model, so request a quote and we will confirm current stock and lead time.
Need help choosing a laboratory hot plate?
ERE Inc. has supplied environmental and laboratory equipment from Montreal for 30+ years. Tell us the vessels, the volumes and the temperature you need, and we will match the plate.
→ Request a Quote | 1-888-287-EREC | Browse Hotplates and Stirrers | sales@ereinc.com
Lire en français : Plaque chauffante de laboratoire : types, matériaux et choix au Canada