SOLINST Drive-Point Profiler Model 660
1.75" (45 mm) dia. | Stainless steel | 4 mm LDPE or PTFE tubing | Peristaltic pump (Model 410) | Max water table depth 26 ft (8 m)
Every water and liquid product ERE carries: groundwater sampling pumps, bailers and liquid samplers, water level meters and dataloggers, water quality instruments, flow, level and pressure instruments, and filtration and treatment, from filter bags to RO and oil-water separators.

1.75" (45 mm) dia. | Stainless steel | 4 mm LDPE or PTFE tubing | Peristaltic pump (Model 410) | Max water table depth 26 ft (8 m)

pH 0–14 ±0.02 | DO 0–500% sat ±1.5% | EC 0–200 mS/cm ±1% | Turbidity 0–1000 FNU ±2% | IP67 meter / IP68 probe | 44,000-sample logger | Up to 140 h battery

pH -2.000 to 16.000 | EC 0.00–500 mS/cm | DO 0.00–45.00 mg/L | 202×140×12.7 mm, 250 g | Data logging 1,000 records, 8-hr battery

500 mL bottle | 5-year shelf life (unopened) | Application-specific formulas (cosmetic, food, dairy, agriculture, industrial) | Airtight tamper-proof bottle | Lot number and expiration date marked

500 mL per bottle | 5-year shelf life (unopened) | Formulations: General Purpose, Proteins, Inorganic Substances, Oil & Fats | FDA-compliant bottle variants available | Airtight tamper-proof seal with lot number & expiration date

500 mL | pH & ORP electrode storage | Reagent-grade KCl formulation | 5-year shelf life (unopened) | FDA-compliant bottle available (HI80300L)

AMCO-AEPA-1 standard | 30 mL bottle | NIST traceable | Non-toxic polymer bead suspension | Ranges: 0/20 NTU (HI93102) & 0/10/500 FTU (HI93703)

84 / 1413 / 12880 µS/cm | NIST-traceable KCl | ISO 3696/BS3978 | 5-year shelf life (unopened) | 500 mL bottle or 20 mL sachets

500 mL bottles | ORP values: 200/275 mV, 240 mV, 470 mV @ 25°C | Acceptance range ±10–20 mV | Reagent grade chemicals | 5-year shelf life (unopened)

O2 Range: 0.00 to 45.00 mg/L | % Saturation O2 Range: 0.0 to 300.0% | Temperature Range: 0.0 to 50.0°C | O2 Resolution: 0.01 mg/L

Range: 0.00 to 9.99; 10.0 to 99.9 & 100 to 1000 NTU | Range Selection: Automatic | Accuracy : ±2% of reading plus 0.02 NTU | Measuring Mode: Normal, Average, Continuous

Turbidity 0.00–1000 NTU (±2% of reading + 0.02 NTU) | Free & total chlorine 0.00–5.00 mg/L (±0.02 mg/L @ 1.00 mg/L)

6 SKUs (0072–0077-SC) | Ranges: 5–150 / 50–1,500 / 500–15,000 mg/L COD | Mercury & mercury-free options | 25 vials/pack, 16 mm optical-quality | Digest 150°C ±2°C up to 2 hrs | EPA-approved method (mercury variants)

30–200°C range | 12 × 16 mm vials | ±0.1°C stability at 100°C | Timer 0–999 min | CE certified | 310 × 250 × 80 mm, 3.6 kg

pH Range: 0.00 to 14.00 pH | EC Range: 0 to 3999 μS/cm | TDS Range: 0 to 2000 ppm (mg/L) | Temperature Range: 0.0 to 60.0°C (32.0 to 140.0°F)

DO: 0–200.0% sat / 0–20.00 ppm (mg/L) | Temp: 0–50°C | Accuracy: ±2% FS (DO), ±1°C (temp) | IP67 waterproof | Altitude comp: 0–20,000 ft | Salinity comp: 0–50 ppt

0–9.99 ppm Total Chlorine | ±10% reading accuracy (0.5–5 ppm) | 0.01 ppm resolution | 15-reading memory | 0–50°C operating range

EC Range: 0 to 3999 µS/cm | TDS Range: 0 to 2000 ppm | Temperature Range: 0.0 to 60.0°C / 32.0 to 140.0°F | EC Resolution: 1 µS/cm

ORP Range: ± 1000 mV | Temperature Range: -5.0 to 60.0°C / 23.0 to 140.0°F | ORP Resolution: 1 mV | Temperature Resolution: 0.1°C / 0.1°F

pH Range: : -2.0 to 16.0 pH | Temperature Range : -5.0 to 60.0°C / 23.0 to 140.0°F | pH Resolution : 0.1 pH | Temperature Resolution : 0.1°C / 0.1°F

±0.05% FS accuracy | Ranges 10m/30ft, 30m/100ft, 60m/200ft, 120m/400ft | 7.5–35 VDC two-wire 4-20mA loop | -20°C to 80°C | 316 SS piezoresistive sensor, vented direct-read cable

32,000 data-set memory | ±0.05% FS typical accuracy | Ranges 10–120 m (30–400 ft) | ~7-yr battery @ 5-min intervals | 316 SS + Delrin body