How the WATERPODS 75™ Works

Contaminated water is pumped through a staged treatment train: a 25-micron bag filter for coarse solids, a 10-micron bag filter for finer particulate, then a carbon (or alternate media) vessel before discharge. The train can be reconfigured by adjusting the valves to suit the contaminant profile.

The carbon stage uses Acid Washed UltraSorber™ bituminous coal carbon (Model No. BC-830) for removal of BTEX, chlorinated solvents and PAH. An optional UltraSorber™ Plus Clay media targets dissolved minerals, oil and grease, and the vessel can be filled half carbon / half clay. Media may need to be filled on site.

Key Specifications

Flowrate75 GPM
Size112" high x 71" long x 71" wide
Maximum Pressure150 psi
BackwashManual backwashable (requires water source)
MonitoringSample ports and gauges
Media ExchangeAccessible top media exchange (rental)
Carbon MediaAcid Washed UltraSorber™ Bituminous Coal Carbon, Model No. BC-830

Options

  • UltraSorber™ Carbon — Acid Washed bituminous coal carbon (BC-830) for removal of BTEX, chlorinated solvents and PAH.
  • UltraSorber™ Plus Clay — selected clay media for removal of dissolved mineral, oil and grease; can be filled half carbon / half clay.

Compounds Removed

  • Benzene, Toluene, Ethylbenzene, Xylenes (BTEX)
  • Trichloroethane, Tetrachloroethene, 1,1,1-trichloroethane, 1,2-dichloroethane
  • Methyl tert-butyl ether (MTBE)
  • Polynuclear aromatic hydrocarbons (PAH)
  • Pesticides, Herbicides
  • Polychlorinated biphenyls (PCB)
  • Chlorine

Applications

  • Excavation dewatering and dewatering
  • Spills
  • Process water and wastewater
  • De-sedimentation (sand or mix-bed media)
  • Potable water