Browse Categories
Fixed Gas Detectors
ERE Inc. carries fixed gas detection systems for continuous monitoring of combustible gases, toxic gases, and oxygen levels. Ideal for industrial plants, refineries, parking garages, and confined spaces. We offer single-point and multi-channel controllers from RKI Instruments ...

Falco 2 Fixed VOC Detector Pumped Model
• Detection Range: 0.01 - 50.0 ppm (TAC) | • Stack Colour: White + Gold Spot | • Lamp: 10.0 eV | • Calibration Points: 2 points

Falco 2 Fixed VOC Detector Diffused Model
• Detection Range: 0.001 - 10 ppm | • Stack Colour: White | • Lamp: 10.6 eV | • Calibration Points: 2 points

Transport Case For Titan 2 Replacement Detector Module
Gas Detection Accessory

Titan 2 Replacement Detector Module
Includes: Transport Case (Part # IS-875405)

Titan 2 Benzene Monitor
• Measuring Frequency: One Minute | • Temperature Stability: Internally heated | • Flow Rate: Sample flow rate ≥ 100 ml/min

LC750 PC120 Built In Type Oxygen Analyzer For Low Concentration Clean Gas
Zirconia cell | 0–10/100/1000 ppm & 0–100 vol% O₂ | Built-in suction pump (1000–2000 mL/min) | ±0.5% FS repeatability | 210×288×327 mm, 10 kg

RKI Instruments Tri Head Gas Detector — Explosion Proof Wastewater Tri-Sensor Head
3 sensors, 1 explosion-proof housing | LEL 0–100% / O₂ 0–25% Vol / H₂S 0–100 ppm | Class I Div 1 Groups B,C,D | UL / CSA NRTL | -40 to 185°F operating (catalytic)

OX-600 O2 Monitor
0–25.0% vol O2 | Resolution 0.1% | Accuracy ±0.7% vol | T90 response <30 s | Alarms 19.0% / 18.0% vol

S2 Series S2 SENSOR / TRANSMITTER
4-20 mA output | Explosion-proof Class I Div 1 Groups B,C,D | Operating temp -40°C to 75°C | Gases: LEL/O2/H2S/CO/CO2/toxics | 11-30 VDC operating voltage

Direct Connect Sensors
LEL 0–100% | O2 0–25% Vol | H2S 0–100 ppm | CO 0–300 ppm | Class I Div. 1 Groups B,C,D | –40°C to 75°C

GD-K88Ai Series TOXIC DIFFUSION SENSOR/TRANSMITTER
4-20 mA output | 15–27 VDC (2-wire loop-powered) | 0–40°C operating | ExiaIICT4 intrinsically safe | 3.9"W × 9.5"H × 1.9"D

EC-600 INDOOR CARBON MONOXIDE GAS MONITOR
CO detection | 0–150 ppm, 1 ppm resolution | Alarms: 50 ppm (L1), 100 ppm (L2) | Electrochemical sensor, field-replaceable | Power: 115 VAC / 24 VDC / 2×AA batteries

M-Series LOW COST TRANSMITTER
24 VDC (11–30 V) | 4–20 mA output | CO: 0–300 ppm / H2S: 0–100 ppm | Electrochemical sensor | 0–120°F operating range

Model 1017 Explosion Proof Sample Draw LEL Sensor
0–100% LEL | 24 VDC input | Sample draw up to 100 ft | 7×7×6.13 in (cast aluminum) | Class I Div I Groups B/C/D (CSA/UL)
Beacon 410A Four Channel Wall Mount Controller
4-channel gas monitoring | NEMA 4X enclosure | 115/220 VAC or 24 VDC | RS-485 Modbus + 4-20 mA outputs | -40°C to 50°C operating range

SAMPLE DRAW SENSOR / TRANSMITTER 35-3001 Model
24 VDC nominal (18.5–30 VDC) | NEMA 4X polycarbonate enclosure | Internal pump, 100 ft sample range | LEL / O2 / H2S / CO / CO2 / H2 sensor options | Optional 4-20 mA output | -20 to 50°C operating range

GD-70D Series INTELLIGENT GAS DETECTOR
DC 24V ±10%, max 4W | 4-20mA / PoE / LonWorks output | Sample draw 0.5 L/min ±10% | 2.8"W × 4.7"H × 5.9"D, 0.9 kg | Operating: 0–40°C, 30–70% RH

RKI Instruments Single / Dual Sensor Air Aspirator
Sample draw up to 100 ft (1/4\" OD tube) | Compressed air: 10–140 PSI | Sample flow: 3 SCFH (1.5 LPM) | Enclosure: IP65 / NEMA 4X (SS or GRP) | Outputs: 4–20 mA, RS485 Modbus

RKI Instruments Digester Gas Monitor
NEMA 4X enclosure | Up to 4 sensors: CH4 0–100% vol, CO2 0–50% vol, O2 0–25% vol, H2S 0–1000 ppm | 100 ft sample range | 4-20 mA + Modbus RTU output | 24"H x 24"W x 10"D

ION SCIENCE SF6 AREACHECK P2
NIC Detection | 0–2000 ppm SF6 | 100–240 VAC 50/60 Hz | IP52 | -5°C to 45°C operating
Beacon™ 800 Eight Channel Wall Mount Controller
8 channels | NEMA 4X weatherproof enclosure | 85-264 VAC / 24 VDC | 4-20 mA inputs (2- or 3-wire) | -10°C to 50°C operating range
Beacon 200 Two Channel Wall Mount Controller
2-Channel | NEMA 4X Enclosure | 110–240 VAC or 24 VDC | 4-20 mA Output per Channel | 10 A Relays (SPDT)

BEACON™ 110
NEMA 4X enclosure | 115/220 VAC or 24 VDC | -20°C to 50°C operating | 10 A SPDT relays (3 total) | 4-20 mA input/output