Department

Calibration Gases

Calibration gas for gas detector bump tests and calibration: Norlab single-gas and multi-gas mixtures in non-refillable steel cylinders (17 to 550 L) and 58 L aluminum cylinders for reactive gases, NIST traceable, plus Dräger and RKI test stations. Request a quote.

3 specialists online · Mon–Fri 8:00–4:30 ET
4 products
SDM-03 DOCKING AND CALIBRATION STATION — Gas Detection Accessory
SDM-03

SDM-03 DOCKING AND CALIBRATION STATION

12 VDC input (100–240 VAC AC adapter) | Operating -10°C to 40°C, ≤80% RH | Compatible: RKI 03 Series gas monitors | Max 200 records standalone / unlimited with PC | Up to 10 modules via USB (PC-controlled mode)

Price on quote · 4 business hours
Drager Bump Test Station
Dräger Bump Test Station

Dräger Bump Test Station

No power required | Compatible: X-am 1700/2000/2500/5000/5600 | Flow rate: 0.5 Lpm | Cylinders: 34/58/103 L | Weight: 5 lbs

Price on quote · 4 business hours
Norlab Multi-Gas and Landfill Calibration Gas Cylinders: H2S / CO / CH4 / O2 in N2 and 50% CH4 / 35% CO2 in N2
NLB-Z105325PM51

Calibration Gases

58 L aluminum (Portagreen) cylinder | 500 PSIG | C-10 outlet (5/8"-18 UNF) | 3.5" dia × 14.5" H | NIST traceable, ISO 9001:2015

Price on quote · 4 business hours
Calibration Gases
NLB-H10135000PN

Calibration Gases

17–550 L non-refillable steel cylinders | 240–2200 PSIG | CGA 600 / C-10 5/8"-18 UNF / CGA 165 outlets | DOT 39 NRC | ISO 9001:2015 + NIST-traceable

Price on quote · 4 business hours

Calibration gas is the certified reference your gas detector is checked and adjusted against, so it has to match the detector's sensors and setpoints. ERE supplies Norlab calibration gases in non-refillable steel cylinders from 17 to 550 L and in 58 L aluminum cylinders for reactive components such as H2S, CO and combustibles. Mixtures are NIST traceable and can be blended to your specification, from single gases to 4-gas confined-space mixes. To automate the routine, the Dräger Bump Test Station needs no power and fits X-am 1700 to 5600 monitors, and the RKI SDM-03 docking station tests and calibrates RKI 03 Series monitors.

Calibration gas FAQ

Which calibration gas do I need?

Match the gas to your detector, not the other way around: the target gases and concentrations are set by the instrument manufacturer and your alarm setpoints. A standard 4-gas confined-space monitor is usually calibrated from one cylinder holding a combustible gas (methane or pentane), oxygen, CO and H2S. Send us the detector make, model and sensors, and we will quote the matching mixture. Our calibration gas guide explains how to read a mixture.

Steel or aluminum cylinder?

Reactive gases such as H2S lose stability in steel, so mixtures that contain them come in treated aluminum cylinders such as Norlab's 58 L Portagreen. Inert and non-reactive gases can use steel cylinders. Size the cylinder to your usage, so the gas is used before its expiry date.

Which regulator fits my cylinder?

The regulator has to match the cylinder outlet and the flow your detector needs. Norlab steel cylinders come with CGA 600, C-10 or CGA 165 outlets, and the 58 L aluminum cylinder has a C-10 outlet. ERE carries regulators for 17 and 34 L steel cylinders and for 29, 34 and 58 L aluminum and 103 L steel cylinders.

What is the difference between a bump test and a calibration?

A bump test briefly exposes the detector to gas to confirm that the sensors and alarms respond; a calibration adjusts the readings to a known concentration. Both use calibration gas, at the intervals set by the manufacturer and your site procedure. Our bump test vs calibration guide explains both.