Skip to content
Agents online · Mon–Fri 8:00–4:30 ET
Montreal HQ · Serving North America
1-888-287-3732
In-house calibration
Fast worldwide shipping
Real tech support
Built by Engineers
Department

Water

Industrial-grade equipment for environmental consultants, oil & gas, mining, manufacturing and labs. Quote-driven catalog — every unit ships with calibration certificates and bilingual technical support.

3 specialists online · Mon–Fri 8:00–4:30 ET
293 products
LaMotte 0074-SC Multi-Range COD Mercury-Free Reagent System. Promag Environmental product image, 800x800 real (sips-veri
LA-0075-SC

Multi-Range COD Reagent Systems

6 SKUs (0072–0077-SC) | Ranges: 5–150 / 50–1,500 / 500–15,000 mg/L COD | Mercury & mercury-free options | 25 vials/pack, 16 mm optical-quality | Digest 150°C ±2°C up to 2 hrs | EPA-approved method (mercury variants)

Quote · 24h response
LaMotte manufacturer WooCommerce original (5-0102.png, resize tokens stripped; -150x150 thumbnail confirms no suffix on
LA-5-0102

COD Heater Block

30–200°C range | 12 × 16 mm vials | ±0.1°C stability at 100°C | Timer 0–999 min | CE certified | 310 × 250 × 80 mm, 3.6 kg

Quote · 24h response
Dissolved Oxygen Tracer — Water Quality Meter
LA-1761

Dissolved Oxygen Tracer

DO: 0–200.0% sat / 0–20.00 ppm (mg/L) | Temp: 0–50°C | Accuracy: ±2% FS (DO), ±1°C (temp) | IP67 waterproof | Altitude comp: 0–20,000 ft | Salinity comp: 0–50 ppt

Quote · 24h response
LaMotte Total Chlorine (TCI) TRACER PockeTester (model 1740) from Poolweb Shopify CDN, original file (no resize tokens).
LA-1740

Total Chlorine Tracer

0–9.99 ppm Total Chlorine | ±10% reading accuracy (0.5–5 ppm) | 0.01 ppm resolution | 15-reading memory | 0–50°C operating range

Quote · 24h response
Hanna ORP Tester
HA-98120

Hanna ORP Tester

ORP Range: ± 1000 mV | Temperature Range: -5.0 to 60.0°C / 23.0 to 140.0°F | ORP Resolution: 1 mV | Temperature Resolution: 0.1°C / 0.1°F

Quote · 24h response
Hanna pHep®4 & pHep®5
HA-98127

Hanna pHep®4 & pHep®5

pH Range: : -2.0 to 16.0 pH | Temperature Range : -5.0 to 60.0°C / 23.0 to 140.0°F | pH Resolution : 0.1 pH | Temperature Resolution : 0.1°C / 0.1°F

Quote · 24h response
4-20mA Pressure Transmitter
4-20mA Pressure Transmitter

4-20mA Pressure Transmitter

±0.05% FS accuracy | Ranges 10m/30ft, 30m/100ft, 60m/200ft, 120m/400ft | 7.5–35 VDC two-wire 4-20mA loop | -20°C to 80°C | 316 SS piezoresistive sensor, vented direct-read cable

Quote · 24h response
Swoffer Model 2100 Series & 3000 Series
SW-2100-STDX

Swoffer Model 2100 Series & 3000 Series

0.1-25 ft/s (0.03-7.5 m/s) velocity range | ±1% accuracy with field calibration | 2" fiber-optic propeller sensor, 4 pulses/rev | 2100: 9V battery; 3000: 4x AA datalogger | 3000 logs 1,000 stations in 100 cross-sections

Quote · 24h response
Spectra FieldPro Peristaltic Pump
WA-SPE-CTRAFIELD

Spectra FieldPro Peristaltic Pump

50–1900 ml/min flow range | 27 ft (8.2 m) max suction lift | 14 hr battery life (low flow) / 9 hr (high flow) | 29 lbs (13 kg) incl. battery | Masterflex EasyLoad II pump head

Quote · 24h response