DrägerSensor XXS are Dräger's miniature electrochemical replacement sensors for oxygen and toxic gases in the Pac single gas and X-am multi gas detectors. Available here for O2, CO, H2S, NO2 and SO2.
- Miniature electrochemical sensors developed and made by Dräger
- Field replaceable in the Pac 6000/6500 and X-am 2500, 2800, 3500, 5000, 5600, 5800 and 8000 (NO2: X-am models only)
- O2 0 to 25 vol %, CO 0 to 2,000 ppm, H2S 0 to 200 ppm, NO2 0 to 50 ppm, SO2 0 to 100 ppm
- Response time t90 of 15 seconds or less (O2: 10 seconds or less)
- Warranty: 3 years O2, CO and H2S; 2 years SO2; 1 year NO2 (Dräger sensor handbook)
- Expected sensor life over 5 years for O2, CO and H2S
Calibrate the detector after a sensor change. Other XXS sensors on request. Request a quote for pricing and availability.
Specifications
- XXS O2 (68 10 881)
- 0 to 25 vol % / 0.1 vol % resolution / t90 10 s or less / -40 to 50 °C / warranty 3 years / life over 5 years
- XXS CO LC (68 13 210)
- 0 to 2,000 ppm / 1 ppm resolution / t90 15 s or less / -40 to 50 °C / warranty 3 years / life over 5 years
- XXS H2S LC (68 11 525)
- 0 to 200 ppm / 0.1 ppm resolution / t90 15 s or less / warranty 3 years / life over 5 years
- XXS NO2 (68 10 884)
- 0 to 50 ppm / 0.1 ppm resolution / t90 15 s or less / -30 to 50 °C / warranty 1 year / life over 2 years
- XXS SO2 (68 10 885)
- 0 to 100 ppm / 0.1 ppm resolution / t90 15 s or less / -40 to 50 °C / warranty 2 years / life over 3 years
- Used In
- Dräger Pac 6000/6500 (O2 / CO / H2S / SO2) and X-am 2500 / 2800 / 3500 / 5000 / 5600 / 5800 / 8000
- Humidity
- 10 to 90 % RH
- Pressure
- 700 to 1,300 hPa
Documents
Calibration and repair
Send it to our Montreal service team. We evaluate the instrument and send a detailed quote before any work starts.
Parts & accessories
-
Price on quote
Questions, answered
How fast will I get a price?
Send the quote request and a specialist replies within 4 business hours, Monday to Friday, 8:00 to 4:30 ET.
Can we pay on account or by purchase order?
Yes. With established credit, terms are Net 30 days, and you can send your purchase order with the quote request. We also accept Visa, Mastercard and American Express.
How is shipping charged?
On quotes and account orders, freight is F.O.B. Montréal: the carrier charge is worked out at shipment from the packed weight and dimensions, and added to your invoice. In-stock items can also be picked up the same day in Montréal (8605 rue du Champ-d'Eau).
Can I return it?
Yes, within 30 days of purchase, with a return authorization number from customer service first. A 25% restocking fee applies, unless it is a defect covered by the warranty. Special orders, hazardous materials, flammable liquids and gases can't be returned. Return policy
Can ERE calibrate or repair it?
Yes. Our Montréal service shop calibrates and repairs it in-house. Request service
What warranty does it carry?
The manufacturer's warranty applies. The exact terms are in the warranty document. Read the warranty
Related equipment we stock

RKI SP-230 Gas Leak Checker (Type FUM / Type SC)
Gases: 50 | Battery Life: 13 hours | Protection: IP67

RKI SC-9000 Portable Multi Toxic Gas Monitor
Gases at Once: 3 | Battery Life: 60 hours | Protection: IP66/68

RKI SC-8000 Portable Toxic Gas Monitor
Sensor Options: 25 toxic gases | Battery Life: 25 hours | Protection: IP67

Dräger X-am® 8000 Multi Gas Detector, 1 to 7 Gases, Pump or Diffusion
Gases: 1 to 7 | Sensor Slots: 5 | Max Hose Length: 45 m