Field Notes

Commercial truck wash bay with OlioSep oil water separator installed at floor drain — ERE Inc.
June 25, 2026

Oil Water Separator for Truck Wash and Fleet Wash Facilities in Canada

By ERE Inc.

Any commercial vehicle wash bay that generates wastewater containing petroleum — diesel engine residue, grease, and wash chemicals — must route that water through an...

Read More
Mobile containerized water treatment system with air stripping tower deployed at a Canadian contaminated site remediation project
June 23, 2026

Soil & Groundwater Remediation Equipment for Canada: A Consultant's Guide

By ERE Inc.

Selecting the right remediation technology for a contaminated site in Canada depends on the contaminant type, site geology, regulatory target, and timeline — not on...

Read More
Industrial liquid filter cartridges arranged upright on stainless steel surface in water treatment facility
June 21, 2026

Industrial Filter Cartridges: How to Choose the Right Type and Micron Rating

By ERE Inc.

Choosing the wrong industrial filter cartridge—wrong type, wrong micron rating, or wrong material—costs money in two ways: premature change-outs if the pore size is too...

Read More
Industrial water treatment facility with pressure vessels containing activated alumina filtration media
June 20, 2026

Activated Alumina for Water Treatment: Guide for Canada

By ERE Inc.

Activated alumina removes fluoride, arsenic, and selenium from water through adsorption — not filtration. It works by binding target contaminants to its highly porous aluminum...

Read More
Calibration gas cylinder with demand-flow regulator connected to a portable gas detector
June 19, 2026

Calibration Gas: Types, Mixtures, and How to Choose

By ERE Inc.

Calibration gas is the certified reference a gas detector is measured against — and choosing the wrong mixture, concentration, or cylinder quietly undermines every bump...

Read More
Safety technician bump testing a portable gas detector with a calibration gas cylinder
June 19, 2026

Bump Test vs Calibration: The Gas Detector Maintenance Guide for Canada

By ERE Inc.

A bump test and a calibration are not the same thing, and confusing them is how a gas detector ends up trusted when it shouldn't...

Read More
Brilliant fluorescent yellow-green fluorescein dye plume dispersing through clear water
June 19, 2026

Fluorescein Dye: Colors, Detection, and Uses in Water Tracing

By ERE Inc.

Fluorescein is the bright yellow-green dye most people picture when they think of water tracing — the vivid plume in a stream or storm drain....

Read More
Field technician pouring fluorescent green tracer dye into a stormwater channel
June 19, 2026

Fluorescent Tracer Dyes: Leak Detection and Water Tracing Guide for Canada

By ERE Inc.

Tracer dyes make invisible water flow visible. Drop the right dye into a storm drain, a septic field, or a process line and you can...

Read More
Technician holding a glass coliwasa sampler showing a separated liquid column beside an open drum
June 19, 2026

Coliwasa Samplers: Types, Use, and Selection Guide for Canada

By ERE Inc.

A coliwasa — short for COmposite LIquid WAste SAmpler — is the standard tool for pulling a representative sample from a drum or tank of...

Read More