Specifications

Specific Gravity Range1.000 to 1.216 Specific Gravity
Specific Gravity Resolution0.001 Specific Gravity
Specific Gravity Accuracy±0.002 Specific Gravity
Sodium Chloride Range0 to 28 g/100 g; 0 to 34 g/100 mL; 0 to 26 °Baume
Sodium Chloride Resolution0.1 g/100 g; 0.1 g/100 mL; 0.1 °Baume
Sodium Chloride Accuracy±0.2 g/100 g; ±0.2 g/100 mL; ±0.2 °Baume
Temperature Range0 to 80°C (32 to 176°F)
Temperature Resolution0.1°C (0.1°F)
Temperature Accuracy±0.3 °C (±0.5 °F)
Temperature Compensationautomatic between 0 and 40°C (32 to 104°F)
Automatic Shut-Offafter three minutes of inactivity
Battery Type/Life9V / approximately 5000 readings
Dimensions192 x 102 x 67 mm (7.6 x 4.01 x 2.6”)
Weight420 g (14.8 oz.)
Refractometer Light Sourceyellow LED
Minimum Sample Volume100 µL (to cover prism totally)

HA-96821 Digital Sodium Chloride Refractometer meets the requirements of the food industry. This optical instrument employs the measurement of the refractive index to determine sodium chloride concentration in aqueous solutions used in food preparation. It is not intended for sea water salinity measurements. The measurement of refractive index is simple and quick and provides the user an accepted method for NaCl analysis. Samples are measured after a simple user calibration with deionized or distilled water. Within seconds the instrument measures the refractive index of the solution. The digital refractometer eliminates the uncertainty associated with mechanical refractometers and is easily portable for measurements where you need them.

Analyze
• Salad dressings
• Cheeses
• Pickles
• Canned foods
• Jarred foods
• Condiments
• Energy drinks
• Milk
• Juices
• Soups
• Brines
• Whey

Specifications
• g/100 g & g/100 mL Range: 0 to 28 & 0 to 34, Resolution: 0.1 & 0.1, Accuracy: ± 0.2 & ± 0.2
• Specific Gravity Range: 1.000 to 1.216, Resolution: 0.001, Accuracy: ± 0.002 
• °Baumé Range: 0 to 26, Resolution: 0.1, Accuracy: ± 0.2
• Temperature Range: 0 to 80°C (32 to 176°F), Resolution: ± 0.1°C (0.1°F), Accuracy: ± 0.3°C (0.5°F)
• Temperature Compensation Automatic between 10 and 40°C (50 to 104°F)
• Approximately 1.5 seconds Measurement Time
• 100 μL Minimum Sample Volume (to cover prism totally)
• Yellow LED
• Stainless Steel ring and flint glass prism
• IP 65 Enclosure Rating
• 9 V Battery Type
• Battery Life: Approx. 5000 readings
• 192 mm x 102 mm x 67 mm (7.6" x 4" x 2.6")