How the UltraVent™ Air Filter Works

Differential static pressure across a filter causes contaminants to accumulate unevenly in the media. The UltraVent™ reversible carbon filter addresses this with a twist-lock flange and end cap that let the filter be reversed, equalizing contaminant distribution and extending unit life.

Conventional cylindrical filters utilize roughly 65% of the available carbon by filtering only through the top section. The UltraVent™ design benefits from 100% of the carbon, and its high-porosity activated carbon removes 99.5% of odors. The filter is available in multiple sizes and CFM ratings.

Key Specifications

ModelRecommendedFlangeOutside DiameterHeightWeightCarbon Bed WidthRecommended FanPressure Drop at Max CFM
UltraVent™ 450ER-450@0.1 sec6"15.4"20" (50 cm)52.4 lbs2.6" (66 mm)V600 & S600180 pa/.75wg
UltraVent™ 650ER-650@0.1 sec6"15.4"30" (75 cm)730.0 lbs2.6" (66 mm)V600 -V800 & S600 & S800180 pa/.75wg
UltraVent™ 900ER-900@0.1 sec6" or 8"15.4"40" (100 cm)100.0 lbs2.6" (66 mm)V600 - V1000 & S600 - S1000180 pa/.75wg
UltraVent™ 1150ER-1150@0.1 sec8" or 10"15.4"50" (125 cm)124.6 lbs2.6" (66 mm)V600 & S600180 pa/.75wg
UltraVent™ 1300ER-1300@0.1 sec10" or 12"15.4"60" (150 cm)152.2 lb2.6" (66 mm)V1000 - V1200 & S1000180 pa/.75wg

Applications

  • Industrial air treatment
  • Commercial air treatment
  • Residential air treatment