Solinst Eureka Underwater Cables, SDI-12 Adapter and Accessories for Water Quality Sondes
Cable Length: 3 to 200 m | Outputs: SDI-12 / MODBUS / RS-232 | Turbidity Standard: 100 FNU
Water quality instruments for the field, the lab and the process line: Hanna multiparameter, pH, DO and turbidity meters and pocket testers, LaMotte testers and COD equipment, and Icon Process Controls inline sensors and controllers. Request a quote.

Cable Length: 3 to 200 m | Outputs: SDI-12 / MODBUS / RS-232 | Turbidity Standard: 100 FNU

Battery Life: 22 hours | Bluetooth: BLE 4.2 | Weight: 0.54 kg

Diameter: 1.95 / 2.95 in | Parameters: 4 / 5 | Warranty: 3 years

Diameter: 3.5 in | Fluorometers: up to 3 | Memory: 1000000+ readings

Diameter: 1.95 in | Length: 14 in | Weight: 1.4 lb

Diameter: 4.0 in | Fluorometers + ISE: 3 + 3 | Memory: 1000000+ readings

Diameter: 3.5 in | Sensors: up to 11 | Memory: 1000000+ readings

Diameter: 1.95 in | Sensors: up to 6 | Memory: 1000000+ readings

Diameter: 2.95 in | Sensors: up to 7 | Memory: 1000000+ readings

Diameter: 2.45 in | Sensors: up to 6 | Memory: 1000000+ readings

Range: 0.00 to 5.00 mg/L | Accuracy: ±0.03 mg/L ±3 % | Protection: IP67

Probe Logging: 140000 measurements | Turbidity: 0 to 1000 FNU | Protection: IP68

Sensor Ports: 3 | Protection: IP68 | Maximum Depth: 20 m

Parameters: pH / ORP / EC / DO | Logging: 45000 records | Protection: IP67 meter / IP68 probe

Pipe Size: 1/2 - 2 in | Wetted Material: PVC / PP / PVDF
from$179.85 CAD
Pipe Size: 2 - 24 in | Wetted Material: PVC / SS
from$149.95 CAD

Max Pressure: 43.5 psi | Max Temperature: 248 F | Wetted Material: PS
$499.65 CAD
Pipe Size: 2 - 8 in | Wetted Material: PVC
from$349.85 CAD
Pipe Size: 2 - 30 in | Wetted Material: PVC / PVDF
from$399.95 CAD

Measuring Range: 0 - 212 F | Accuracy: ±0.5 % FS | Output: 4-20mA
from$599.95 CAD

Measuring Range: 0 - 500 mS/cm | Output: 4-20mA + RS485 + relays | Power: 9 - 36 VDC
from$1,449.85 CAD

Output: 4-20mA + RS485 + relays | Power: 9 - 36 VDC or 100 - 240 VAC
Measuring Range: 0 - 500 mS/cm | Output: 4-20mA + RS485 + relays | Power: 9 - 36 VDC
from$1,449.85 CAD

Measuring Range: pH -2 to 16 / ORP -2000 to 2000 mV | Output: 4-20mA + RS485 + relays | Power: 9 - 36 VDC
from$1,299.85 CAD
ERE carries water quality instruments for three settings. In the field, the Hanna HI9829 multiparameter meter measures up to 14 parameters, including pH, ORP, dissolved oxygen, conductivity and turbidity, with a 44,000-sample logger; single-parameter meters cover dissolved oxygen and turbidity, and pocket testers check pH, conductivity and TDS. In the lab, the Hanna edge® measures pH, conductivity and DO, and LaMotte supplies a COD heater block and COD reagents. On the process line, Icon Process Controls sensors measure conductivity, dissolved oxygen, turbidity and pH/ORP continuously, and controllers such as the U900 and D720 send 4-20 mA, RS485 and relay outputs.
ERE also stocks calibration solutions and repairs and calibrates water quality meters.
For groundwater sampling, where pH, dissolved oxygen, conductivity, temperature and ORP are usually read together, a multiparameter meter saves swapping probes in the field. For a single parameter, a dedicated meter or a pocket tester is simpler. Our water quality meter guide compares the options.
A portable meter takes spot readings in the field or the lab. An inline sensor stays in the pipe or tank and feeds a controller continuously, which can drive alarms through relays and send data over 4-20 mA or RS485. The Icon U900 takes four sensors plus a temperature channel on one 7 in. touch screen.
Before each day of use, and again if the meter was turned off, unless the maker says it holds calibration. Calibrate at pH 7.01 first, then at 4.01 or 10.01 so the two points bracket the pH you expect to measure. Our pH buffer guide explains the choice.
Yes. ERE's repair and calibration service covers pH, conductivity, dissolved oxygen, turbidity and multiparameter water quality meters, including Hanna instruments, with a calibration certificate on every service.