LUMINOR's RAINIER 6.0 model of UV water treatment systems is feature laden and includes a discrete 254nm Teflon™-based UV sensor and integral 4-20mA output and solenoid ready capabilities. Manufactured from 316L stainless steel, these pressure vessels are designed & manufactured to ASME standards. A bayonet style lamp connector allows for easy lamp change without the need for additional tools. For increased power density, RAINIER incorporates low pressure, amalgam (LP-AM) coated UV lamps offering a consistent output over their 12,000 hour rated life. Monitoring is provided through an integral LED display which in addition to the UV output, displays remaining lamp life, total running hours, audible & visual lamp failure and remote-on. Whether you are looking to control issues in both hot or cold water with UVT levels as low as 50% or to reduce TOC in industrial grade waters, RAINIER has you covered.
RAINIER 6.0, Light Commercial Amalgam UV Systems, non-monitored | ||||||
Part Number | LU-LR6-355 | LU-LR6-555 | LU-LR6-855 | LU-LR6-1105 | LU-LR6-1405 | LU-LR6-1755 |
Flow Rate 30 mJ/cm² @ 95% UVT (Industry Std.) | 35 gpm | 58 gpm | 85 gpm | 140 gpm | 180 gpm | 215 gpm |
132 lpm | 208 lpm | 322 lpm | 530 lpm | 681 lpm | 814 lpm | |
8.0 m³/hr | 12.5 m³/hr | 19.3 m³/hr | 31.8 m³/hr | 40.9 m³/hr | 48.8 m³/hr | |
Alternate Flow Rate 16 mJ/cm² @ 95% UVT (US Public Health)* | 66 gpm | 109 gpm | 167 gpm | 266 gpm | 377 gpm | 406 gpm |
250 lpm | 413 lpm | 632 lpm | 1007 lpm | 1276 lpm | 1537 lpm | |
15.0 m³/hr | 24.8 m³/hr | 37.9 m³/hr | 60.4 m³/hr | 76.5 m³/hr | 92.2 m³/hr | |
Alternate Flow Rate 40 mJ/cm² @ 95% UVT | 26 gpm | 44 gpm | 57 gpm | 106 gpm | 135 gpm | 163 gpm |
98 lpm | 167 lpm | 216 lpm | 401 lpm | 511 lpm | 617 lpm | |
5.9 m³/hr | 10.0 m³/hr | 12.9 m³/hr | 24.1 m³/hr | 30.7 m³/hr | 37.0 m³/hr | |
Port Size | 1½" | 2" | 2" | 2½" | 3" | 4" |
Electrical | 230V / 50-60Hz (IEC power cords required) | |||||
Plug Type | North American NEMA 6/15: "5" suffix | |||||
Lamp Watts | 104 | 152 | 207 | 304 | 344 | 414 |
Power (watts) | 120 | 170 | 220 | 320 | 360 | 430 |
Replacement Lamp | RL-500A | RL-720A | RL-1000A | RL-720A (2 required) | RL-843A (2 required) | RL-1000A (2 required) |
Replacement Sleeve | RQ-500 | RQ-720 | RQ-1000 | RQ-720 (2 required) | RQ-843 (2 required) | RQ-1000 (2 required) |
Chamber Material | 316l Stainless Steel, A249 Pressure Rated Tubing, polished & Passivated | |||||
Reactor Dimensions | 4x27.2x5.6" | 4x35.8x5.6" | 4x46.8x5.6" | 6x35.8x7.9" | 6x40.6x7.9" | 6x46.8x7.9" |
Controller Dimensions | 11.8 x 7.9 x 6.3" (30.0 x 20.1 x 16.0 cm) | |||||
Maximum Operating Pressure | 10.3 bar (150 psi) | |||||
Operating Temperature Range | 2-40° C (36-104° F) | |||||
UV Monitor | Upgradeable, includes visual glow plug | |||||
Remote-On | Yes, with optional 210010 cable | |||||
Dry Contacts (solenoid ready) | ||||||
4-20 mA Output | ||||||
Lamp Age Counter | Yes | |||||
Lamp-Out Indicator (audible & visual) | ||||||
*Note | Based on flow velocity of 8.2 ft/s (2.5 m/s), flow rates are limited by port sizes: |